ULVAC VACUUM > Gas analyzers > Gas analyzers > Software for Gas Analysis Qulee QCS
Software for Gas Analysis Qulee QCS
![]() |
||
|
||
|
Qulee QCS is a software for gas analyzers and process monitors of ULVAC. This software has basic functions for gas analysis and process monitoring; peak-intensity monitoring, leak testing and recipe-based monitoring. The operation of the data acquisition and the saving data is carried out by simple clicking. The software includes another functions in addition to basic functions; background subtraction, measured area integration, data saving as CSV format, and controlling more than one sensors through RS485-interface. "Qulee QCS" suits for various needs such as gas analysis, process monitoring, and research and development. Our old model, that includes QCS 2001 or MSQ-400, MM200 etc., can upgrade to "Qulee QCS".
- Easy operation with enhanced short cut button.
Simultaneously control of up to 8 units (in free combinations of models)
Measurement-condition control by recipe setting
Easy leak check in the helium leak test mode
Simultaneously recording analog data in 2 channels
Setting 2 points for partial pressure set point output (in the trend-mode measurement)
Includes background subtraction and measured area integration
Saving a data as a data format that can be loaded into spreadsheets (CSV format)
| Specifications | |
| Model | Qulee QCS |
| OS | Windows 98, 2000, XP, Vista |
| Interface | RS-232C/485 (via a converter for RS-485) |
| Sensor Number | Free combination of up to 8 sensors of various models (with RS485) |
| Sensor model | REPROS/SEPION/STANDAM/ST-400 |
| Recipe | 100 (70 in the user area) |
| Sweep speed | 50, 100, 200, 500, 1000, 2000 msec/mass |
| Sampling interval | Auto, 0.5 - 1000 sec (in the trend mode) 1 - 1000 sec (in the scan mode) |
| Measurement end time | Continuous, or free setting |
| Measurement mode | Scan mode : Measuring the mass spectrum in various mass range (model dependent) |
| Trend mode : Measuring partial pressure to time up to 20 channels | |
| Leak-test mode : One-touch helium leak testing | |
| Analog mode : Analog wave measurement for mass number calibration | |
| Sensitivity-calibration mode : Calibration of the sensitivity of the SEM detector | |
| DEGAS mode : Controlling the electron bombardment type outgassing of ionsource (only SEPION) | |
| Indication of gas composition name | Able to indicate the gas composition name in scan and trend modes |
| Function | Background subtraction Integration of measured area |
| Analog Input | 0 - 10V (2 points) |
| Set-point | Partial pressure set-points in 2 channels (Error and warning)(only in trend mode) |
| Electron energy for ionization | 20 - 70eV (only REPROS), fixed (only in sensor-built-in type) |
| Status Check | Error detection (communication error, filament break, RF error, interlock) Total running time of Filament and SEM |
| Display | Vertical axis : Linear and the logarithmic selectable. Display range selectable [Current (A), partial pressure (Pa), concentration (ppm)] |
| Horizontal axis : Mass number (scan mode and analog mode) and time (trend mode). Able to change and scroll the Horizonal axis range. Indicate saved data (able to indicate saved data during measurement) Bar chart and line chart is simultaneously indicated. |
|
| Data save | Auto save, or saved after measurement The file is named by combination of time and date at starting point of measurement. (Auto save). Filename is selectable. Saving place can be set. File can be converted to CVS format. Record of sensitivity calibration can be saved in text format. |
| Print data | Graph displayed in scan, trend or analog mode can be printed. Setting screen range to be printed Setting data color & radius of trend graph |
| Option | RS-232C/485 converter, PC |
| Recommendation of PC | HDD : 2 MB (except measurement data), RAM: 128 MB or more |
| CPU : Pentium 200 MHz or higher, display area: 800 x 600 or more, COM port, CD-ROM drive |