ULVAC VACUUM > Vacuum Pumps > Dry Pumps > Eco-Shock Power-Saving Attachment
Eco-Shock Power-Saving Attachment
![]() |
||
|
||
|
Eco-Shock is a groundbreaking attachment that can be attached to your existing dry pumps to achieve great savings in dry pump power consumption.
- Greatly reduces dry pump power consumption.
No drop in evacuation speed at full pressure
Simple installation
- Dry pumps used to evacuate inert gases such as air, nitrogen or argon.
Dry pumps used with sputtering or loading / unloading chambers.
| Model | ES10 | |
| Power supply | Voltage, frequency, phase | 100 to 220 VAC, 50
/ 60 Hz, single-phase (switched automatically) 65W |
| Power consumption | ||
| Control | Input | Remote start / stop (24 VDC contact with voltage) Non-voltage contact with contact capacity of 2.0 A min. required CLOSE : Start; OPEN : Stop |
| Output | Overcurrent alarm output (non-voltage contact) Contact capacity : 24 VDC, 1.0 A |
|
| Operation | Manual start switch | |
| Display | Display of operation time | |
| Appearance | Dimensions | Eco-Shock : 175 x 310 x 240 mm Valve unit : 66 (diameter) x 110 mm (NW40) |
| Weight | Eco-Shock : 8.3 kg; Valve unit : 800 g |
|
| Connection | Connection port | G1/4" (INLET , OUTLET) |
| Recommended piping | Diameter : 6.53 mm
min. ; Length : 3 m max. |
|
| Manufacturer | ULVAC | ||||
| Model | LR60 | LR90 | LR180 | ER80 | ER150 |
| Evacuation speed (L/min) (*1) |
1300 | 2100 | 3980 | 1300 | 2500 |
| Measured power consumption (kW) (*2) |
2.1 | 3.6 | 6.6 | 1.3 | 1.5 |
| Measured power consumption with Eco-Shock attached (kW) (*2, *3) |
0.7 | 1.0 | 1.6 | 0.3 | 0.3 |
| Power reduction rate | 69% | 72% | 76% | 77% | 80% |
*1 At 60Hz power.
*2 Power consumption at ultimate pressure.
*3 Including power consumption of ECO-SHOCK.